Programming
Machineconfiguration
Programmingincludesmachineconfiguration(1or2motors,coinboxornocoinbox),operating
ranges(thedesiredsettings-language,times),andlastlythedefinitionofthebehaviorofeach
singledryingcycle.
Allprogrammingphasesstartbyenteringthecorrectpassword,afterwhichtheoperatorproceeds
toenterthedesiredparameters.
AllprogrammingphasescanbestoppedatanytimebypressingSTOP.Allparametersenteredup
tothatpointwillbestored,exceptforthecurrentone.
Alltemperaturerangevalueslistedinthefollowingtablesareexpressedin°C.Incasetheboardis
configuredforoperationin°F,allvalueswillbeautomaticallyconverted.
Thepasswordrequiredtoaccessthisphaseis748.Proceedasfollows:presskeysUPand1atthe
sametime.WhenthemessagePASSWOisdisplayed,pressENTER.
Themessage00000appears,pressthreetimestheDOWNkeytoerasethreezeroesstartingfrom
theright,thentypein748andpressENTER.Actualprogrammingstartsnow.
Inthefollowingtable,programmingissummarizedwiththemessagethatappearsonthedisplay,
thevaluesallowedwhenprogrammingafterpressingENTERandthemeaningofeachparameter.
Programming
DISPLAY ALLOWEDVALUES DESCRIPTION
DISPLA 0..2 Displaymode,showingwhichdatawillbedisplayedduring
thedryingcycle.Availablevaluesare:
0Residualtime/Temperature
1Residualtime
2Temperature
GETSN Yes/No Coinboxoperation
INVSN Yes/No ReversingEnable.Yesifthemachineisequippedwith
reversing,otherwiseNo.