Settingtheoperatingranges
Thepasswordrequiredtoaccessthisphaseis916.Proceedasfollows:pressbothkeysUPand
1atthesametime.ThemessagePASSWOisnowdisplayed,thenpressENTER.
Thedisplaynowshows00000.PresstheDOWNkeythreetimestoerasethreezeroesstarting
fromtherightandthentypeinthepassword916.PressENTER.Actualprogrammingstartsnow.
DISPLAY ALLOWEDVALUES DESCRIPTION
CELSIUSSN Yes/No Yes-ProgramsanddisplaysinCelsius.
No-ProgramsanddisplaysinFahrenheit.
ANTICREASE
SN
Yes/No Anti-creases.Enablesordisablestheanti-wrinklefeatureat
theendoftheprogram.
CYCLETIME 0..99(min) Cycletime.
Thisparameterspecifiesdurationofthedryingcycle.
TROTATION 10..200(sec) Rotationtime(onlyifreversingisenabled).
Thisparameterindicatesthemaximumdurationinseconds
ofrotationenteredintheprograms.
TPAUS 10..250(sec) Rotationpausetime(onlyifreversingisenabled)
Thisparameterindicatestheminimumtimethatthebasket
muststopforbetweenonemotionreversalandthenext.
°HEAT 30..99(°C) Heatingtemperature.
Establishesthemaximumtemperaturevaluethatcanbe
programmed.
TIMECOOL 0..15(min) Cooldowntime.
Thisparametersetsthemaximumdurationofthecooldown
timeforeachindividualprogram.
°COOLING 20..50(°C) Cooldowntemperature.
Themaximumtemperaturethatcanbesetforeachprogram
inordertoconsidercooldownfinished.